Retaining Wall – Combined Waterproofing and Damp Proof Membrane

HomeRetaining Wall – Combined Waterproofing and Damp Proof MembraneRetaining Wall – Combined Waterproofing and Damp Proof Membrane

Photo 1

Photo 2

Photo 3

We recently completed work on a new build property in Nottinghamshire.  Our client required a waterproofing system for the lower ground floor. 

In line with NHBC requirements for floor levels greater than 600mm below ground we installed a combined waterproofing system:

  • Type A: Barrier Protection – external waterproofing
  • Type C: Drained Protection – internal waterproofing

External Waterproofing Type “A”

Primary resistance of the structure was provided by Koster bitumen-based waterproofing on the positive side:

  • Installation of a serviceable drain positioned below the slab level to run around the perimeter of the retaining walls as a method of risk reduction.

Internal Waterproofing Type “C” (Drained) Protection 

Secondary protection, which manages any water ingress which occurs as a consequence of an installation defect, was provided by a cavity drain membrane system.

Wall Cavity Drain Membranes

Walls:  8mm cavity drain membrane was fixed to the internal side of the external cavity and taped into the wide DPC at the beam and block junction.  Photo 3

  • Fillet along the wall/floor junction using repair mortar.
  • Wall membrane trimmed to 40mm from smoothing fillet.
  • Damp proof membrane taped to floor membrane with Waterseal Tape.

Nottinghamshire, July 2025